back

Products Detail

menu

ZBL-P8100 Dynamic Foundation Pile Detector

  • Introduction
  • Main Parameter
  • Photos
  • Comment

Introduction of ZBL-P8100 Dynamic Foundation Pile Detector

1. ZBL-P8100 Dynamic Foundation Pile Detector equipped with large touch screen, user friendly interface, easy to learn and master

2.Dual-channel simultaneous sampling, multi-directional testing for each pile makes the work more efficiently

3.Wavelet processing can effectively collect reflecting signal from pile bottom, exceeds international standards

4.The systems advanced design accurately stores the wave form image, and multiple channel signals can be saved for each tested pile

5.Real time on-site test wave can be treated with smoothing, differential, filtering, power exponent and linear amplification wave processing methods

6.The signal noise can be eliminated by taking the superposition of multiple signals. The superposition can be viewed at any time, allowing the poorer quality signals to be ignored

7.Files arranged by projects   piles; clear and convenient, project/pile testing data can be easily accessed, edited, or deleted

8.Standard USB port, thumb drive can be used for updating software; convenient and reliable

Parameter of ZBL-P8100 Dynamic Foundation Pile Detector

Item

Specifications

Item

Specifications

Control Mode

Embedded platform,Win CE Operation System

Monitor

8.4 inch,high brightness,TFT Color LCD

Data storage

2GB,SD card

Operation Mode

Touch screen

Trigger

Signal trigger

Ports

USB port

Noise voltage of the system

≤2 mV

Dynamic range

³184 dB

Amplifier frequency range

1Hz~10kHz

Input impedance

³1 MW

Sampling time intervals

6µs~64ms

Time resolution

6µs

Max length of sampling

³1024

Gain error

≤1 dB

Amplitude nonlinear degree

≤10%

Timing accuracy

≤1%

Floating point magnification (time)

1~256

Sentinel magnify (time)

1~1,000,adjustable

A/D resolution

16 bit A/D,8 bit floatingpoint

Max magnify (times)

256000

Number of channels

2

Transducer sensitivity

³100 mv/g(acceleration mode)

Consistency of phase position
of two channels

±3° or 0.05ms

Frequency range of 
Transducer

0.5~9000 Hz(acceleration mode)

Amplitude consistency of two channels

≤3% or ≤±0.2dB

Continuous operating hours

>5 hrs

Interference between channels

≤1%

Power

AC:220V±10%,DC:+12V

Dimensions

256mm´188mm´63.5mm

Weight

2.3kg(lithium battery included)


Photos of ZBL-P8100 Dynamic Foundation Pile Detector

Comment of ZBL-P8100 Dynamic Foundation Pile Detector

Your Name

Email or trade@chinacoalintl.com

Tel/Wechat/Whatsapp or +8615376502802 Your Tel

CountryYour Country

Enquiry

Related Products +