The C310A Steel Rebar Corrosion Tester Detection Equipment includes a two-electrode handle system which provides flexibility for the operator to:
Test using one electrode based on half cell potential method.
Test using two electrodes based on gradient method. In both cases, electrodes used are copper sulfate type.
Automatic storage option is available in instrument -
Data transfer to USB-thumb drive is available.
The Steel Rebar Corrosion Tester Detection Equipment device generates rebars corrosion potential contour graph
Software Provided for Data Processing of Corrosion Potential Measurement: Is an Easy Way to Use Powerful processing software
provided for generation of reports Operates on windows based computers.
Items |
Specifications |
|
Corrosion detection method |
single electrode |
Double electrode |
Measuring Range(mV) |
±1000 |
0-1000 |
Accuracy(mV) |
±0.1 |
±0.1 |
Tested points Interval X |
0-100 adjustable |
20 fixed, |
Tested points Interval Y |
0-100 adjustable |
0-100 adjustable |
Screen |
160x128 |
|
Battery operating Time(h) |
>40 |
|
Power |
Built-in rechargeable lithium battery |
|
Data transmission |
USB thumb drive storage |
|
Data storage |
234 points |
|
Test area(m²) |
234( tested point interval 100cm) |
|
Size(mm) |
212x134x50 |
|
Electrode Size(mm) |
30x180 |
|
Weight(kg) |
0.9 |